Product Information
​
-
The H2F-CU12FM Water Flow Meter is designed to be fitted into water lines ONLY to display flow per minute & total litres used
-
This flow meter is perfect for stationary installations such as water filters, water coolers & dispensers, irrigation & electronic projects as well as hydroponics and machinery cooling systems
-
This flow meter is NOT suitable for fuels
​
​
Fitting Recessed Display
-
The LCD Polarised Display on the H2F-CU12FM Water Flow Meter is designed to be only visible when viewed from horizontal and below. When viewed from this angle the display is extremely clear
-
Using the display as a template mark out hole and cut to suit
-
Fix in position with bolts provided or suitable screws
​
​
Connecting Sender Unit (refer diagram below)
​
-
The sender unit must be installed in the horizontal position
-
The thread specification of the sender unit are 1/2" BSP Male
-
Make sure the sender is fitted with the water flow in the direction of the arrow
noting that flow direction is one way
-
The display comes pre-wired with an approximately 1.4m sender cable
-
Extra 1.4m & 3m extension leads are available for the three pin plugs
-
Up to 6 leads may be joined to make 9.8m in total length
-
Please Note: Sender leads cannot be cut and joined – this will void your warranty, extension leads must be used
​
​
Connection to 12Volt DC Adapter
-
It is recommended that you get the 12v power from the ignition or a separate switch
-
Simply cut off the two pin 12v plug to the required length and connect the black wire to the negative terminal and the red wire to the positive power source
-
The back-light will stay ON when connected to 12v
-
All settings and amounts will be stored if power is disconnected
Current use at 12Volt DC Adapter
​
-
1 mA when operational
-
0.015 mA when asleep
-
Please Note: 1,000 mA (milliamp) = 1 A (amp)
​
Programming & Display Selection
​
-
Press "DISPLAY" button to turn display on the screen
-
To set the Display for the 1/2" sender supplied you will need to press both buttons at the same time & release. "H22" is the setting that you need displayed
-
If "H22" is not displayed, continue to press and release the "DISPLAY" button until "H22" is displayed
-
Press "DISPLAY" button again this will display the accumulated flowing volume (flow totalisation) or real time flow rate
-
Press and release "RESET" button for four seconds which will reset the total measuring volume to zero
-
All settings and amounts will be stored when the screen turns off
-
Please Note: The maximum monitoring capacity is 99,999 litres
​
Operating
​
-
The Topargee H2F-CU12FM Water Flow Meter will automatically turn on when there is water flowing through the sensor
-
It will automatically turn off 10 seconds after there is no water flowing
-
Blue back-light remains on unless a switch is fitted in power line
​​
​
Reset
​
-
Press and hold the "RESET" button for 4 seconds
-
The total measuring volume will be reset to 0
​
​
Specifications
​
-
​Colour White
-
Power 12 Volt DC
-
Mounting Recessed Mount
-
Screen LCD Polarised Display
-
Sender Lead 1.4 Meters
-
Ext Lead Option Yes
-
Connection Size 1/2” BSP Male
-
Flow Rate 1.5 - 25 LPM (90 - 1500 LPH)
-
Flow Rate Display LPM & total amount
​​
​
Please Note: flow will be restricted if maximum flow rate is exceeded. Check BEFORE purchasing / fitting
​
-
Pressure Max 6 bar (87 psi)
-
Temperature 0 to 60℃ (32 to 140℉)
-
Suitable for Fuels No
-
​Suitable for Water Yes
-
Displays Litres or Gallons Yes
-
Weight 140 g (5.38 oz)
-
Accuracy +/- 5%
-
​Materials Sensor Body - Glass filled PPS
Turbine - PA Composite
Turbine Holder - Acetal Copolymer
Shaft of Turbine - #304 Stainless Steel
O-Ring - EPDMR
Control Unit Housing - ABS resin
​
​
​
​
​
​
​
​
​
Please Note: Due to continuous product improvement, specifications are subject to change without notice
​
Downloadable Installation Guide
​
​
​
​